Oslo - Oslo

Rockefeller Auditorium

Sist oppdatert 25/09/2016

Innlast:

Fra gateplan og opp bratt innvendig bakke(15 m). Traller til utlån.

15 m til scenekant

Scene:

11 x 6 m, 1,35 høy. 6,9 m klarning til lysrigg

Dimmerland:

54x 3KW Standard 8 bit dimmer channels.

Strøm:

There is a total of 330A/230V 3phase available for use through two seperat distributions.

First distribution is a total of 250A/230V 3phase and is distributed amongst :

54 16A/230V 1phase dimmerchannels ( see note *2 in riggplot)

11 16A/230V 1phase patchable outlets in dimmerpatch for distribution throug stage multicables. Available on request:

One 63A 3phase 400V CEE from transformer located on stage left ( see note *4 in riggplot)

One 90A 3phase 400V powerlock available from same transformer located on stage left. ( see note *5 in riggplot) Use of powerlock requires electrician on duty.

Second distribution is a total of 80A/230V 3phase and can be distributed through either one off: One 3phase 80A/230V CEE ( see note *3 in riggplot).

One 3phase 63A/230V CEE ( see note *3 in riggplot).

One 1phase 63A/230V CEE ( see note *3 in riggplot)

One 44A/400V 3phase transformer with breakoutbox containing one 3phase 63A/400V CEE, two 3phase 32A/400V CEE, three 1phase 16A/230V CEE, six 1phase 16A/230V schuko. ( see note *1 in riggplot)

Lysutstyr:

Lysmikser:

1x Grand MA2 Light, software version 3.1.2.5

Lamper:

56x 1KW Par 64, CP61

2x 6 bar, 1KW Par 64, CP61 as frontlight

10x 1KW Par 64, short nose – floor model

6x Clay Paky Mythos in 34 channel vector mode

8x Clay Paky K10 B-Eye in 35 channel shapes mode

2x 8 bar 250W, Par 64 ACL

5x Two way 4-lights blinders (4x 650W)

3x Atomic 3000 strobes

1x Juliet Foxy MSR 700 followspot, følgespot i fast posisjon på balkong.

2x MDG ATMe installed in fixed positions

1x Martin Magnum 2000 (Use generates fee due to use of extra fireguards)

4x Manfrotto floorstands

6x Microphone stands

Trekk:

Trossegrid over scenen

2 x 1250 Kg. motorer tilgjengelig for produksjon(en)

Oppbevaring av tomkasser:

Ved scene

Sal:

1300 kapasitet stående. 2 balkonger

Mikserposisjon:

Sentrert ca 11 m fra scenekant. Gulvnivå. Kan og flyttes til 1 balkong

Lydanlegg:

PA:

8 x EAW KF750F

4 x EAW KF755F

4 x EAW SB750Fi

8 x EAW SB1000z

Delaysystem :

6 x EAW FR129z

FOH :

Midas Heritage 2000

Monitor:

Midas Heritage 3000

12 x Turbosound TFM-450 biamped 15” / 2” wedge

Sidefills :

2 x d&b C4 tops

4 x d&b C4 subs

Drumfill :

Turbosound TQ-425 2x15” sub

Mikrofoner:

2 x Shure Beta 91A

2 x Shure Beta 52

8 x Shure Beta 58A

1 x Shure Beta 57A

2 x Shure SM 58

8 x Shure SM 57

4 x Shure KSM 137

5 x Sennheiser 904

2 x Sennheiser MD 421

2 x Sennheiser 906

2 x Audio Technica AE3000

2 x Audio Technica AT4040

2 x Neuman KM 184

10 x BSS AR 133 active DI

2 x Countryman active DI

2 x MTR active DI

Stativer:

2 x Tall boom stand, round base

14 x K&M tall with boom

12 x K&M small with boom

Akustikk:

God

Mat:

Catering og Restaurant i samme bygg

Garderober:

ja bak scene, stort oppholdsrom

Adresse:

Torggata 16

0181 OSLO

Kontaktperson Teknisk:

Technical manager/Teknisk sjef

Ørjan Bjørnevik

direkte: 22 03 48 24

E-mail: orjan(@)rockefeller.no

Hotel:

Ja, alle alternativer

Avstand Hotel-Spillested:

300 m

Taxi:

Hjemmeside:

www.rockefeller.no

Administrativ Kontakt:

Bo Hustoft

direkte: 22 03 48 01

E-mail: bo(@)rockefeller.no

Vegard Engelsvoll

direkte: 22 03 48 14

E-mail: vegard(@)rockefeller.no

Joakim Throndsen

direkte 22 03 48 26

E-mail: joakim(@)rockefeller.no

Postadresse:

Auditorium AS

Rockefeller/John DEE/Sentrum Scene

Badstugata 2

0181 Oslo

Telefon:

22 20 32 32

Sorter etter